| Local Properties | ||
Managed Object Types | Data Object Types | All Properties | All Methods |
Properties
Name | Type | Description |
---|---|---|
baseUnits | xsd:string |
The base units in which the sensor reading is specified. If rateUnits
is set the units of the current reading is further qualified by the
rateUnits. See rateUnits |
currentReading | xsd:long |
The current reading of the element indicated by the sensor. The actual
sensor reading is obtained by multiplying the current reading by the
scale factor.
|
healthState* | ElementDescription |
The health state of the of the element indicated by the sensor.
This property is populated only for sensors that support threshold
settings. See HostNumericSensorHealthState |
name | xsd:string |
The name of the physical element associated with the sensor
|
rateUnits* | xsd:string |
The rate units in which the sensor reading is specified. For example if
the baseUnits is Volts and the rateUnits is per second the value
returned by the sensor are in Volts/second.
|
sensorType | xsd:string |
The type of the sensor. If the sensor type is set to Other the sensor
name can be used to further identify the type of sensor. The sensor
units can also be used to further implicitly determine the type of the
sensor. See HostNumericSensorType |
unitModifier | xsd:int |
The unit multiplier for the values returned by the sensor. All values
returned by the sensor are current reading * 10 raised to the power of
the UnitModifier.
|
Properties inherited from DynamicData | ||
dynamicProperty, dynamicType |
Top of page | Local Properties | ||
Managed Object Types | Data Object Types | All Properties | All Methods |